On-line intermittent connector anomaly detection
Shared by EDWARD BALABAN, updated on Dec 25, 2013
Summary
- Author(s) :
- Antonio Ginard, Irfan Ali, Jonathan Goldin, Irtaza Barlas, Patrick Kalgren, Michael Roemer, Edward Balaban
- Abstract
This paper investigates a non-traditional use of differential current sensor and current sensor to detect intermittent disconnection problems in connectors. An intermittent disconnect, often resulting in an arc, creates an imbalance which is manifested in the current. The traveling wave generated due to the perturbation can be detected using current sensors. This paper shows the feasibility to detect disconnection based on this principle.
- Publication Name
- N/A
- Publication Location
- N/A
- Year Published
- N/A